NETGEAR GS700TR Switch User Manual


 
GS700TR Smart Switch Software Administration Manual
2-36 Configuring System Information
v1.0, May, 2008
2. Click Apply to updated the switch. The changes take effect but will not be retained across a
power cycle unless a save is performed.
LLDP-MED Interface configuration
Use this page to enable LLDP-MED mode on an interface and configure its properties.
To display this page:
1. Click System > LLDP > LLDP-MED > Interface Configuration in the navigation tree. A
portion of the web screen is shown below.
Figure 2-22
Table 2-23. LLDP Global Configuration Fields
Field Description
Fast Start Repeat
Count
Specifies the number of LLDP PDUs that will be transmitted when the protocol
is enabled. The range is from 1 to 10. The default value is 3.
Device Class Specifies local device's MED Classification. The following three represent the
actual endpoints:
Class I Generic [IP Communication Controller etc.]
Class II Media [Conference Bridge etc.]
Class III Communication [IP Telephone etc.])
The fourth device is Network Connectivity Device, which is typically a LAN
switch/router, IEEE 802.1 bridge, IEEE 802.11 wireless access point, etc.