Nortel Networks 9150 Network Router User Manual


 
106 Remote Gateway 9150 Installation and Administration Guide
Installing the Remote Gateway 9150 unit Standard 3.1
The analog device must be located no farther than 307.7 meters
(1000 feet) from the Remote Gateway 9150 unit.
! Ethernet cable
If you are connecting the Remote Gateway 9150 unit to a hub, you need a
standard CAT5 un-shielded twisted-pair (UTP) straight-through Ethernet
cable. The cable must be no longer than 100 meters (325 feet) in length.
Connector and pin-out reference
The following table identifies where to find the pin-out table for each connector:
More information
The following documents describe how to establish telephone and trunk
connections using the Meridian 1 PBX BIX in-building cross-connect system:
! Meridian 1 PBX Installation planning (NTP 553-3001-120)
! Telephone and attendant console installation (NTP 553-3001-215)
! BIX* In-Building Cross-Connect System Material Installation and
Servicing (Wall-Mounted System) (NTP 631-4511-200)
Connector Connection type For the pin-out table, refer to
TELCO 1 25 TIP and RING pairs page 404.
TELCO 2 25 TIP and RING pairs page 406.
ETHERNET RJ-45 page 408.
ADMIN DB-9 page 409.
Power DIN page 410.