Nortel Networks 9150 Network Router User Manual


 
Remote Gateway 9150 Installation and Administration Guide 447
January 2005 Display log definitions
Statistic Definition
LOG NUMBER 49
DESCRIPTION This log indicates that an unknown remote tried to connect and the
attempt failed.
SEVERITY WARNING
TASK Network Manager
PRODUCT RLC, 9150, 911x
CANCELLATION None
ACTION TO BE TAKEN 1) Confirm that the configuration of the unit IDs are OK between the
units.
2) This may be an indication of an unauthorized Remote Gateway
9100 Series unit attempting to connect.
PARAMETERS 1) Unit ID of the Remote Gateway 9100 Series unit
DISPLAYED TEXT Message from invalid Remote Site: P1
LOG NUMBER 50
DESCRIPTION This log indicates that a connection came in on an unconfigured
port and was rejected by the system. (PSTN connections)
SEVERITY WARNING
TASK Network Manager
PRODUCT RLC, 9150
CANCELLATION None
ACTION TO BE TAKEN 1) Check for proper port configurations on the RLC and Remote
Gateway 9150 unit.
2) Check if a local call came in on a remote-only BRI port. Ensure
that non-remote only BRI trunk numbers only are given to
outsiders to call 9150's local sets.
3) Unauthorized unit may be trying to connect. Verify!
PARAMETERS 1) PSTN number from which the call originates
DISPLAYED TEXT Incoming connection rejected. Address P1