Nortel Networks 9150 Network Router User Manual


 
Remote Gateway 9150 Installation and Administration Guide 109
January 2005 Installing the Remote Gateway 9150 unit
Connecting the Remote Gateway 9150 unit to the network
To connect the Remote Gateway 9150 unit to the network:
1 Connect the male 50-pin connector of the telephone cable to the TELCO 1
connector on the Remote Gateway 9150 unit.
Secure the cable connection by snapping the wire tabs into place or by
inserting screws.
2 Establish the connections to the telephones and trunks according to the
pin-out table in “TELCO 1 connector pin-out table” on page 404 (in
Appendix C).
3 Connect the Remote Gateway 9150 unit to the Ethernet network if you want
to route calls over the IP network, or administer the Remote Gateway 9150
unit from another location, by doing the following:
a. Connect one end of the RJ-45 Ethernet cable to the ETHERNET
connector on the Remote Gateway 9150 unit.
b. Connect the other end to an Ethernet hub.
4 Connect the male 50-pin connector of the other telephone cable to the
TELCO 2 connector on the Remote Gateway 9150 unit.
Note: Secure the cable connection by snapping the wire tabs into place or
by inserting screws.
5 Establish the connections to the telephones and trunks according to the
pin-out table in “TELCO 2 connector pin-out table” on page 406 (in
Appendix C).
. W
WARNING
Risk of electric shock or damage to equipment
To reduce the risk of electric shock to yourself or damage to
the Remote Gateway 9150 unit, ensure that the power source
to the unit is turned off until the Telco 1 and Telco 2
connections have been completed.