Nortel Networks NN43001-314 Server User Manual


 
Zone parameters 257
Procedure 23
Configuring the MG 1000B zone
Step Action
WARNING
Before and after an upgrade, perform a datadump (using LD 43
EDD or NRS Manager) on the CPPM or MGC to back up the
existing data.
1
Set the current date and time. See Software Input Output
Administration (NN43001-611).
LD 2 Define system date.
Command
Description
STAD dd mm yyyy hh mm ss
Set the time and date:
STAD DAY MONTH YEAR HOUR MINUTE SECOND
2
Configure the Home Location Code (HLOC) and Virtual Private
Network Identifier (VPNI).
LD 15 Configure Customer Data Home Location Code and Virtual Private Network Identifier.
Prompt Response Description
REQ: NEW CHG Add new data, or change existing data.
TYPE: NET ISDN and ESN Networking options
CUST Customer number
0-99
Range for Large System and CS 1000E system
0-31
Range for Small System and Media Gateway 1000B
...
CLID YES Allow Calling Line Identification Option
- ENTRY
xx
CLID entry to be configured
- - HLOC
100-9999999
Home location code (ESN) (3-7 digits)
ISDN YES Integrated Services Digital Network
- VPNI (0)-16383 Virtual Private Network Identifier for Bandwidth
Management Feature
0 or X = disables feature
1-16383 = enables feature
<cr> = no change
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314 01.02 Standard
Release 5.0 20 June 2007
Copyright © 2007, Nortel Networks
.