Nortel Networks 24T Switch User Manual


 
Using the Console Interface
309985-B Rev 00
3-55
Choose High Speed Flow Control Configuration (or press h) from the Switch
Configuration Menu screen to open the High Speed Flow Control Configuration
screen.
Figure 3-23. High Speed Flow Control Configuration Screen
Table 3-20 describes the High Speed Flow Control Configuration screen fields.
Table 3-20. High Speed Flow Control Configuration Screen Fields
Field Description
Unit
Allows you to select the unit number (when stacking is configured) to view or
configure. To view or configure another unit, type its unit number and press
[Enter], or press the spacebar to toggle the unit numbers (the system only
displays a screen for units that are configured with a gigabit MDA).
Autonegotiation
When enabled, the port only advertises support for 1000 Mb/s operation, in
full-duplex mode.
Default Value Enabled
Range Enabled, Disabled
(continued)
High Speed Flow Control Configuration
Unit: [ 2 ]
Autonegotiation: [ Enabled ]
Flow Control: [ Disabled ]
Preferred Phy: [ Right ]
Active Phy: None
Use space bar to display choices, press <Return> or <Enter> to select choice.
Press Ctrl-R to return to previous menu. Press Ctrl-C to return to Main Menu.