Nortel Networks TP-1610 SIP Network Router User Manual


 
Mediant 2000 SIP User’s Manual J. SS7 Tunneling
Version 4.4 237 July 2005
Table J-4: SS7 Signaling Link (continues on pages 236 to 237)
ini File Parameter Name Description
SS7_LINK_GROUP_ID
Determines the group ID (M3UA) of signaling link.
The valid range is 0 to 0xFFFF. The default value is 0.
ATM_SAAL_LINK_PROFILE_NUM
Determines the ATM SAAL Link profile number
The valid range is 0 to (MAX_SAAL_PROFILES-1). The default value is 0.
ATM_SAAL_LINK_TYPE
Determines the ATM SAAL link Type PVC/SVC
The valid range is ATM_VCC_TYPE_PVC to ATM_VCC_TYPE_SVC. The
default value is ATM_VCC_TYPE_PVC.
ATM_SAAL_LINK_PORT_NUM
Determines the ATM SAAL link port num
The valid range is 0 to ATMDB_ATM_MAX_INTERFACES_RANGE. The
default value is 0.
ATM_SAAL_LINK_VPI
Determines the ATM SAAL link VPI
The valid range is 0 to 255. The default value is 0.
ATM_SAAL_LINK_VCI
Determines the ATM SAAL link VCI
The valid range is 0 to 0xFFFF. The default value is 0.
SS7_LINK_TNL_MGC_LINK_NUMBER
Determines the MTP2 Tunneling: MGC link number (MTP2 \other side\ of
signaling link.
The valid range is 0 to 7. The default value is 0.
SS7_LINK_TNL_ALIGNMENT_MODE
Determines the MTP2 Tunneling: Alignment mode of signaling links in
tunnel.
The valid range is 0 to 255. The default value is
M3B_ALIGNMENT_EMERGENCY.
SS7_LINK_TNL_CONGESTION_MODE
Determines the MTP2 Tunneling: Congestion mode of signaling links in
tunnel.
The valid range is 0 to 255. The default value is
M3B_CONGESTION_ACCEPT.
SS7_LINK_TNL_WAIT_START_COMP
LETE_TIMER
Determines the MTP2 Tunneling Timer: wait start complete.
The valid range is 500 to 0xFFFFFFFF. The default value is 30000.
SS7_LINK_TNL_OOS_START_DELAY
_TIMER
Determines the MTP2 Tunneling Timer: OOS start delay.
The valid range is 500 to 0xFFFFFFFF. The default value is 5000.
SS7_LINK_TNL_WAIT_OTHER_SIDE_I
NSV_TIMER
Determines the MTP2 Tunneling Timer: wait other side inservice.
The valid range is 500 to 0xFFFFFFFF. The default value is 30000.
SS7_LINKSET_SN_INDEX
Determines the first index field for line.
The valid range is 0 to 1. The default value is 0.
SS7_LINKSET_LINKSET_INDEX
Determines the second index field for line.
The valid range is 0 to 7. The default value is 0.
SS7_LINKSET_ROWSTATUS
Determines the RowStatusField for line.
The valid range is acPARAMSET_ROWSTATUS_DOESNOTEXIST to
acPARAMSET_ROWSTATUS_DESTROY. The default value is
acPARAMSET_ROWSTATUS_DOESNOTEXIST.
SS7_LINKSET_ACTION
Determines the management field for actions.
The valid range is acSS7LINKSET_PS_ACTION_NONE to
acSS7LINKSET_PS_ACTION_DEACTIVATE. The default value is
acSS7LINKSET_PS_ACTION_NONE.
SS7_SN_ACTION_RESULT
Determines the management field for actions result.
The valid range is acPARAMSET_ACTION_RESULT_SUCCEEDED to
acPARAMSET_ACTION_RESULT_FAILED. The default value is
acPARAMSET_ACTION_RESULT_SUCCEEDED.
J.5 SS7 MTP2 Tunneling ini File Example
For the SS7 MTP2 tunneling ini file example, note the following:
The first ini file acts as an MTP2 tunneling central side (M2UA MGC links).