Table L-2: acBoardConfigurationError Alarm Trap
Corrective Action: Inspect the run-time specific string to determine the nature of the configuration error. Fix
the configuration error using the appropriate tool: Web interface, EMS, or ini file. Save
the configuration and if necessary reset the device.
Table L-3: acBoardTemperatureAlarm Alarm Trap
Alarm:
acBoardTemperatureAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.3
Default Severity
Critical
Event Type:
equipmentAlarm
Probable Cause:
temperatureUnacceptable (50)
Alarm Text:
Board temperature too high
Status Changes:
Condition: Temperature is above 60 degrees C (140 degrees F)
Alarm status: Critical
Condition: After raise, temperature falls below 55 degrees C (131 degrees F)
Alarm status: Cleared
Corrective Action: Inspect the system. Determine if all fans in the system are properly operating.
Table L-4: acBoardEvResettingBoard Alarm Trap
Alarm:
acBoardEvResettingBoard
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.5
Default Severity
Critical
Event Type:
equipmentAlarm
Probable Cause:
outOfService (71)
Alarm Text:
User resetting board
Status Changes:
Condition: When a soft reset is triggered via the Web interface or SNMP.
Alarm status: Critical
Condition: After raise
Alarm status: Status stays critical until reboot. A clear trap is not sent.
Corrective Action: A network administrator has taken action to reset the device. No corrective action is
required.
Table L-5: acFeatureKeyError Alarm Trap
Alarm:
acFeatureKeyError
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.6
Default Severity
Critical
Event Type:
processingErrorAlarm
Probable Cause:
configurationOrCustomizationError (7)
Alarm Text:
Feature key error
Status Changes:
Note: Support of this alarm is pending
Condition: A feature key error has been detected
Alarm status: Critical