Nortel Networks TP-1610 SIP Network Router User Manual


 
Mediant 2000 SIP
Mediant 2000 SIP User’s Manual 242 Document #: LTRT-72504
Table J-5: Table of Parameter Values Example - Remote Management Connections
Index Fields:
1. Connection Number
Connection
Number
User Name User Password Time Connected (msec) Permissions
0 Admin Yellow9 0 All
1 Gillian Red5 1266656 Read Only
2 David Orange6 0 Read Write
Table J-6: Table of Parameter Values Example - Port-to-Port Connections
Index Fields:
1. Source Ports
2. Destination IP
3. Destination Port
Source Port Destination IP Destination Port Connection Name Application Type
2020 10.4.1.50 2020 ATM_TEST_EQ LAB_EQ
2314 212.199.201.20 4050 ATM_ITROP_LOOP LAB_EQ
6010 10.3.3.41 6010 REMOTE_MGMT MGMT
J.6.1 Table Indices
Each line in a table must be unique. For this reason, each table defines one or more Index fields.
The combination of the Index fields determines the 'line-tag'. Each line-tag may appear only once.
In the example provided in Table J-5, there is only one index field. This is the simplest way to
mark lines.
In the example provided in Table J-6, there are three Index fields. This more complicated method
is a result of the application it represents.
J.6.2 Table Permissions
Each field in a line has a 'permission' attribute, which determines if and when the user may
modify the field.
There are several types of permissions:
Read - The user may read the value of a field (true for all fields).
Write - The user may modify the value of the field at any time.
Create - The user must provide a value for the field at creation time.
The default values set for all fields already determine the initial values.
Maintenance write - The user may modify the value of the field only when the entity
represented by the line is in maintenance state.
Each table includes rules to determine when it is in a maintenance state.
In the example in Table J-5, ‘User Name’ and ‘User Password’ fields have Read-Create
permissions. The ‘Time Connected’ field has Read-Only permission, and the ‘Permissions’ field
has a Read-Create-Maintenance_write permission.