– 46 –
11-3. USB Interface Model
ON ON
OFF OFF
DIP-SW 1
Switch Function ON OFF
1-1
Command emulation (Ster Line mode) Always ON
1-2
Should not be changed (Should be set to on)
1-3
Should not be changed (Should be set to on)
1-4
Sensor adjustment Invalid Valid
1-5
USB mode Printer class Vendor class
1-6
Handshaking conditions (conditions for
BUSY)
Ofine or receive
buffer full
Receive buffer full
1-7 Automatic status back function *1
Invalid Valid
1-8
Should not be changed (Should be set to on)
1-9
Low-power consumption mode Invalid Valid
1-10
Should not be changed (Should be set to on)
*1 Automatic status back function is disabled when USB mode is Printer Class (switch 1-5 =
ON).
The factory settings of DIP switch are all on.
DIP-SW 2
Switch Function ON OFF
2-1~2-4
Always ON Should be set to on
The factory settings of DIP switch are all on.
No. 1 2 3 4 5 6 7 8 No. 1 2 3 4
9 10
DIP-SW 1 DIP-SW 2