Omega RD100B Microcassette Recorder User Manual


 
12-10
Name Display Example Description
1-channel digital display
2-channel digital display
4-channel digital display
6-channel digital display
(Dot model)
4-channel bar graph display
(Pen model)
1-channel digital display
+ 1-channel bar graph display
2-channel digital display
+ 2-channel bar graph display
6-channel bar graph display
(Dot model)
Flag display
Channel ID alarm status
display
Date/time and chart speed
display
1-channel digital display
+ 4-channel bar graph display
(Pen model)
Channel No.
Alarm Measured
value
Unit
Measurement channel
Measurement channel
Measurement channel
Measurement channel
Measurement channel
Computation channel
Computation channel
Computation channel
Computation channel
Computation channel
Channel No. (1 digit), alarm (1 digit),
measured value (7 digits), unit (6 digits)
Channel No. (1 digit), alarm (1 digit),
computed value (9 digits), unit (6 digits)
Channel No. (1 digit), alarm (1 digit),
measured value (7 digits), unit (6 digits)
Channel No. (1 digit), alarm (1 digit),
computed value (9 digits), unit (6 digits)
Channel No. (1 digit), alarm (1 digit),
measured value (6 digits)
Bar graph, scale
Channel No. (1 digit), alarm (1 digit),
computed value (6 digits)
Bar graph, scale
Displayable values are –19999 to 99999 and a
decimal. If this range is exceeded, the value
is displayed as“–####” or “+####.”
Channel No. (1 digit), alarm (1 digit),
measured value (6 digits)
Bar graph, scale
Bar graph, scale
Flag, scale
Displays the date/time on the left and chart
speed on the right.
Alarm is not set.
– Alarm is not occurring.
Channel No. Alarm is occurring.
Measured value (5 or 6 digits)
Channel No. (1 digit), alarm (1 digit),
measured value (6 digits), unit (3 digits)
Bar graph, scale, alarm (bar graph)
Value and bar graph of the same channel.
Channel No. (1 digit), alarm (1 digit),
computed value (6 digits)
Displayable values are –19999 to 99999 and
a decimal. If this range is exceeded, the value
is displayed as“–####” or “+####.”
Channel No. (1 digit), alarm (1 digit),
measured value (6 digits), unit (3 digits)
Displays using 5 × 7 dots when the unit
exceeds 3 digits.
Channel No. (1 digit), alarm (1 digit),
computed value (9 digits)
AH9999999.9
1H3000.0ABC
1H3000.0ABC
1H-1999.9ABCDEF
2L 2000.0PQRSTU
AH-999999.9ABCDEF
BL9999999.9PQRSTU
999.9 999.9 999.9
999.9 999.9 999.9
AH
-1
999.9 BH
-1
999.9
CH9999.9 DH9999.9
1H3000.0 1H3000.0
3H3000.0 4H3000.0
AH
-1
999.9 BH9999.9
1H-1999.9ABCDEF
Sep.21.2004 1200
11:26:37 mm/h
AH9999999.9ABCDEF
1H3000.0 2L-999.9
12.4 Display Function Specifications