Setting the Rear Switches
I/O port
RS-422A
RS-232C
Synchronization
Internal
External
OFF
ON
CTS
0 V
External
I/O port selection (selector switch)
Set this to RS-422A.
Unit # (DIP SW1)
Set SW1-1 to SW1-5 to OFF (0).
Synchronization (selector switch)
Set this to Internal.
Communications speed
(DIP SW2-1 to SW2-4)
1-to-1/1-to-N selection (DIP SW2-6)
Set SW2-6 to OFF (0) (1-to-N).
Instruction level (DIP SW2-7, SW2-8)
Set these switches to ON (1).
(Levels 1, 2, and 3 are enabled.)
CTS selection (selector switch)
Set this always to 0 V (ON).
Terminator
Terminator setting (selector switch)
Set this switch to ON.
ON
ON
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
SW1
SW2
Set these switches to 1010 to select
9600 bps.
(0: OFF 1: ON)
Set these switches to 0010 to select
19200 bps.