Panasonic FP Server User Manual


 
FP Web-Server V2.11
7.1 Details on the FP Web-Server's Web Page Functions
91
the SIZE="x" command. Secondly, this string can be shortened even further with
the format command .xs. Thirdly, the maximum memory permitted (Header 1st
Word) has to be taken into account. After the transmission of the string to the PLC,
the "header" (2nd Word) with the new length will be updated.
- Un-initialized String: If a string variable is not initialized by the FPWIN Pro project,
the 1st Word (maximum string length) is zero. With this the FP Web-Server cannot
store any character in this string because no memory is reserved for storing!
- Null-String: If such a string has the length 0 (zero) the current length of the string
(2nd Word) is also set to 0, i.e. the string is deleted.
A string (s or S) of an input field (determined by MEWTOCOL) can only be 48
characters long! Compare to display fields for strings that are 52 characters
long!
The special characters < and > are transcribed as ¼ and ¾ characters when
the strings are displayed. If the special characters ¼ and ¾ are used in input
fields, they will be transcribed into the characters < and > before they are
transmitted to the PLC.
Only 7-bit ASCII characters (see page
99) are supported when strings are
displayed or entered in HTML.
7.1.12.3 Comments on Defining Input Fields for PLC Data on HTML
In the current version only DT, FL and LD values can be defined in input fields. The input
of internal relay values (R, Y) has to be realized via hyperlinks in the format, as it is
described under Calling Parameter (see page
73).
In the definition of the input field NAME="DT205_6_d", only numbers from 0 to 9, letters
from A to Z and the underscore are permitted! Please do not use special characters like
* - < > $ % / ' & and so on!
The data type and address part TTxxxy can be replaced by the corresponding variable
name (see page
82) from the FPWIN Pro project, e.g. {'VarName'_aa_bb} or
{'name'_5_i}.
In the current version, octal numbers cannot be entered, i.e. format specifier _o has not
been implemented yet!
The "default" MEWTOCOL address of the PLC cannot be modified by the calling
parameter "Address Modifier" &A=x for input fields!
In case "A) Send Input with Button" where several input fields can be sent to the PLC
with a button, the maximum number of characters of all NAME="..." commands is limited
to 300. The number of characters of all VALUE="..." commands is limited to 300 as well.
You can limit the PLC write access with the function [Add. Range].
For programming examples in C++ and Java to send PLC data via http submit function to the
PLC refer to the online help under the keyword "Appendix K) Programming Samples: Access to
the FP Web-Server / PLC via TCP".