Panasonic KX-TDA100 Network Router User Manual


 
2.9 Connection of 2.4 GHz Portable Stations
Installation Manual 189
Using a DHLC/DLC Card
Refer to the following example to connect a CS to the Hybrid IP-PBX.
Accessories and User-supplied Items for the CS
Accessories (included): Screws × 2, Washers × 2
User-supplied (not included): RJ11 connector
Note
For details about DHLC card or DLC card, refer to "2.5.2 DHLC8 Card (KX-TDA0170)", "2.5.3 DLC8
Card (KX-TDA0171)", or "2.5.4 DLC16 Card (KX-TDA0172)".
Signal Name
D1
D2
DHLC/DLC card
(Amphenol)
Cable Maximum Distance
ø 0.4 mm: 222 m
ø 0.5 mm: 347 m
ø 0.6 mm: 500 m
CAT 5: 347 m
Signal Name
Pin No.
1
2
3
4
D1
D2
CS (RJ11)
DHLC8 Card