2.4 Information about the Trunk Cards
Installation Manual 95
Switch Settings
Pin Assignments
RJ45 Connector for Trunk Use
RJ45 Connector for Extension Use
BNC (coaxial) Connector (TX)
Switch Type Usage and Status Definition
Termination Slide Select 120 (default) or 75 to match the connector type to be
used.
A/B Slide When using an RJ45 connector, select A (default) for trunk or B for
extension use.
When using BNC connectors, make sure that A is selected.
No. Signal Name Level [V] Function
1 RX+ (+) Receive data (+)
2 RX- (-) Receive data (-)
3 Reserved
4 TX- (-) Transmit data (-)
5 TX+ (+) Transmit data (+)
6-8 Reserved
No. Signal Name Level [V] Function
1 TX- (-) Transmit data (-)
2 TX+ (+) Transmit data (+)
3 Reserved
4 RX+ (+) Receive data (+)
5 RX- (-) Receive data (-)
6-8 Reserved
No. Signal Name Level [V] Function
1 TX+ (+) Transmit data (+)
2 TX- (-) Transmit data (-)