2.10 Connection of Doorphones, Door Openers, External Sensors, and External Relays
198 Installation Manual
2.10 Connection of Doorphones, Door Openers,
External Sensors, and External Relays
2.10.1 Connection of Doorphones, Door Openers, External
Sensors, and External Relays
The Hybrid IP-PBX supports a maximum of 16 doorphones (KX-T30865 with a DPH4 card, or German-type
doorphone with a DPH2 card), 16 door openers, 16 external sensors, and 16 external relays.
Notes
• KX-T30865 is a Panasonic doorphone.
• German-type doorphones, door openers, external sensors, and external relays are user-supplied.
Maximum Cabling Distance
Installing the Doorphone (KX-T30865)
1. Loosen the screw to separate the doorphone into 2 halves.
Cable Maximum Distance
ø 0.4 mm: 70 m
ø 0.5 mm: 113 m
ø 0.6 mm: 180 m
CAT 5: 113 m
Doorphone
Door Opener
External Sensor/
External Relay Device