Precautions for use
ENGLISH - 13
Important
Information
■
Cautions when setting up the projector
z
To install and use the projector via a method that does not use the adjustable feet in a oor standing
installation, x the projector using the ve screw holes for ceiling mounting (as shown in the diagram).
(Screw diameter: M6, tapping depth inside the set: 12 mm (15/32"), torque: 4 ± 0.5 N·m)
z
Use the adjustable feet only for the oor standing installation and for adjusting the angle. Using it for other
purposes may damage the set.
Screw holes for ceiling mount (M6)
Adjustable feet
z
Do not stack projectors on top of each other.
z
Do not use the projector tilted at an angle that exceeds ±15° from the horizontal plane.
z
Do not block the ventilation ports (intake and exhaust) of the projector.
z
Prevent hot and cool air from the air conditioning system to blow directly to the ventilation ports (intake and
exhaust) of the projector.
500 mm (20") or longer 500 mm (20") or longer 500 mm (20") or longer
100 mm (4") or longer
z
Do not install the projector in a conned space.
When it is necessary to install the projector in a conned space, install the air conditioning or ventilation
separately. Exhaust heat may accumulate when the ventilation is not enough, triggering the protection
circuit of the projector.
z
Make a clearance of at least 20 mm (0.8") between the projector bottom and setting surface by inserting
spacers (metallic) etc. between them.