Table 1-1
General Technical Specifications
Specifications Criteria
APPROVALS
FCC Part 15
FCC Part 68
UL
3615 DualFlow DSU
3616 DualFlow DSU,
3000 Series Carrier
CSA
Safety
3615 DualFlow DSU
3616 DualFlow DSU,
3000 Series Carrier
Emissions
Bell Canada
Class A digital device
AW292J-61661-DD-N
Listed UL 1950, second edition
Recognized Component UL 1950, second edition
Certified CSA 22.2, No. 950-M89
Certified Component CSA 22.2, No. 950-M89
CSA 108.8 – M1983, Class A digital apparatus
“DCTE Specifications,” July 1989, Issue 1
AC POWER REQUIREMENTS
3615 DualFlow DSU
3616 DualFlow DSU
3000 Series Carrier (16 DualFlow DSUs,
plus SDU and fan module)
24 Vac (CT), 60 HZ ± 3 (0.115 amp, 9.5 watts at 115 Vac)
24 Vac (CT), 60 Hz +3 (0.080 amp, 8.0 watts at 115 Vac)
90—132 Vac, 60 Hz +3 (1.650 amp, 165 watts at 115 Vac)
DTE INTERFACE
3615 DualFlow DSU
25-pin D-subminiature connector
34-pin connector
3616 DualFlow DSU with
25-Pin V.35 Interface
Uses a Rear Connector Plate with two
25-pin D-subminiature connectors.
EIA-232-D/CCITT V.24 (ISO 2110)
CCITT V.35 (ISO 2593)
EIA-232-D/CCITT V.24 (ISO 2110)
CCITT V.35 (ISO 2593)
(A V.35 Interconnect Cable is required to use the V.35 connector. The
cable provides an interface between the DSU’s 25-pin D-type connector
and the DTE cable’s V.35 connector.)
ENVIRONMENT
Operating Temperature
Storage Temperature
Relative Humidity
Shock and Vibration
32°
to 122
° F (0°
to 50
° C)
–4°
to 158
° F (–20°
to 70
° C)
5%—95% (noncondensing)
Withstands normal shipping and handling
HEAT DISSIPATION (MAX.) AT 115 VAC
3615 DualFlow DSU
3616 DualFlow DSU
3000 Series Carrier (16 DualFlow DSUs
plus SDU and fan module)
29.00 Btu/hr
27.30 Btu/hr
563.00 Btu/hr
NMS COMPATIBILITY
COMSPHEREr 6700 Series NMS, Release 4.0 or greater
COMSPHEREr 6800 Series NMS, Release 4.1.5 or greater