Paradyne 3616 Network Card User Manual


 
Unit Configuration
5-133615-A2-GB20-20 December 1996
Table 5-4
(1 of 3)
DBM Port Configuration Options
DTE Port: 232
Next 232 V.35 Prev
DTE Port
. Selects which DTE port will be used for DBM data. This configuration option is forced to 232 (EIA-232) unless
Primary Core
is set to Yes.
232 For the EIA-232-D connector, the maximum cable length from the DBM to the router is 34 feet with
shielded cable and 68 feet with unshielded cable when operating at 56 kbps.
V.35 Only appears if Primary Core (DBM option set) is set to Yes. For the V.35 connector, all rates are
available for distances up to 1000 feet.
RTS Cntrl: FrcOn for DiDg, DTE for other configurations
Next FrcOn DTE Prev
Request-to-Send Control
. This configuration option determines how the DBM will function with respect to the RTS lead.
FrcOn The DBM keeps the internal RTS ON continuously, regardless of whether RTS at the DTE interface is ON
or Off. FrcOn should be used when the DBM is connected to the console port of a router since the router
does not support RTS signalling.
DTE The DBM responds to RTS from the router.
CTS Cntrl: Std
Next Std =RTS FrcOn Prev
Clear-to-Send Control
. Controls the behavior of the CTS lead.
Std CTS is normally controlled by the router’s RTS lead; however, the CTS lead can be affected by the
response to abnormal conditions, such as no signal or test mode.
=RTS CTS follows RTS.
FrcOn CTS remains ON as long as the DSU has power.
AntiStream:Disab
Next Chang Prev
Antistreaming
. Antistreaming provides circuit protection against a streaming DTE (a defective DTE that has its RTS lead
constantly turned ON) by clamping the RTS lead of the tributary DBM.
If the tributary DTE turns ON RTS longer than the time specified for the Antistreaming configuration option, the tributary
DBM turns on its alarm indicator and clamps RTS to Off. Although the tributary DTE is not allowed to send, the DBM can
still respond to commands and is capable of being tested or disabled.
Upon detecting that RTS is no longer turned ON, the DBM turns Off its alarm and resets the streaming timer, and allows
the DTE to send data once again.
This configuration option only has an effect at a DBM configured with
RTS Cntrl
set to DTE.
Chang Set timer to Disab, or to any value from 1 to 100 second(s) in increments of 1. When Disab is selected,
streaming terminal detection is not provided.
LSD Lead: Std
Next Std FrcOn Prev
Line Signal Detect Lead
. Controls behavior of the Line Signal Detect lead.
Std LSD lead goes Off in response to a loss of carrier or a switched network failure.
FrcOn Keeps LSD on as long as the DBM has power.