Paradyne 3821PLUS Network Card User Manual


 
COMSPHERE 3821Plus Modem
3-26 February 1998 3821-A2-GB20-30
Table 3-5
(2 of 5)
DTE Dialer Configuration Options
*Escape GuardTim: 1sec
Nxt 1sec 200msec 400msec 600msec 800msec 2sec
Escape Guard Time. Determines the length of the required pause before and after the escape sequence is issued. The
guard time prevents the modem from interpreting data as the escape sequence characters.
The factory default is 1 second.
AT command equivalent is S-register S12=
n
.
*BreakForceEscap: Disable
Nxt Disable Enable
Break Forces Escape. Determines whether or not the modem should enter Command mode when it receives a break
character from the DTE.
Disable – A break character is sent to the remote end.
Enable – Modem escapes into AT Command mode, and a break character is not sent to the remote end.
The factory default is Disable.
AT command equivalent is \K
n
.
*CommandCharEcho: Enable
Nxt Enable Disable
Command Character Echo. Controls whether or not characters are echoed back to the DTE when the modem is in
Command mode.
The factory default is Enable.
AT command equivalent is E
n
.
*CarriageRtn Char: 013 ASCI
Nxt 013 ASCI
Carriage Return Character. Allows you to change the ASCII character used to terminate an AT command to any ASCII
value from 0 to 127.
The factory default is 013 (ASCII carriage return).
AT command equivalent is S-register S3=
n
.
*Backspace Char: 008 ASCI
Nxt 008 ASCI
Backspace Character. Sets the character used to perform a backspace in Command mode.
The factory default is 008 (ASCII backspace character).
AT command equivalent is S-register S5=
n
.
* This configuration option only appears if DTE Dialer Type is configured for AT.