Paradyne 7112 Network Card User Manual


 
MIB Descriptions
C-16
7112-A2-GB20-10March 1998
Table C-7. DS1 Near End Group Configuration Table Objects (4 of 4)
Object, OID, Access Setting/ContentsDescription
dsx1SignalMode
(dsx1ConfigEntry 11)
1.3.6.1.2.1.1.10.18.6.1.11
read-only
This object specifies
whether Robbed Bit
Signaling (RBS) is being
used. This object differs
from the MIB definition in
that it is not read/write.
RBS is not supported in this
product.
Supports the following value:
H none(1) – No signaling is
being used on this
interface.
dsx1TransmitClock–
Source
(dsx1ConfigEntry 12)
1.3.6.1.2.1.1.10.18.6.1.12
read-only
This object specifies the
timing source for the
transmit clock for this T1
interface. This object differs
from the MIB definition in
that it is “read-only” (not
read/write) for DSU/CSUs.
Supports the following
values:
H loopTiming(1) – The
recovered receive clock is
being used as the transmit
clock.
H localTiming(2) – The
DSU/CSU’s internal clock
is used being as the
transmit clock.
H ThroughTiming(3) – The
recovered receive clock
from another interface
(e.g., network or
synchronous data port) is
being used as the transmit
clock.
dsx1Fdl
(dsx1ConfigEntry 13)
1.3.6.1.2.1.1.10.18.6.1.13
read-write
This object specifies how
Facility Data Link is being
used.
More than one value may be
active at a time.
Supports the following
values:
H dsx1other(1) – SNMP
data is being sent over
FDL.
H dsx1Ansi-T1-403(2)
ANSI PRMs are supported
on the network interface as
specified by ANSI T1.403.
H dsx1Att-54016(4) – FDL
supports the requirements
specified by AT&T
publication TR54016.
H dsx1Fdl-none(8)
Indicates that the device
does not use FDL.