Paradyne 7112 Network Card User Manual


 
Testing
7-3
7112-A2-GB20-20
March 1998
Running Network Tests
Network tests require the participation of your network service provider. To
access the Network Tests screen, follow this menu selection sequence:
Main Menu
Test
Network Tests
main/test/network PARADYNE
Device Name: Model: 7112
NETWORK TESTS
Test Command Status Result
Local Loopbacks
Line Loopback: Start Inactive 0:00:00
Payload Loopback: Start Inactive 0:00:00
Repeater Loopback: Start Inactive 0:00:00
Remote Loopbacks
Send Line Loopback: Up
Send Inactive 0:00:00
Pattern Tests
Send: QRSS Start Active 0:00:00
Monitor: QRSS Start Active 99:08:48 – Errors 99999+
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
Use the Command column to start or stop a test by pressing Enter. The Result
column displays the test duration since the last device reset. When the Monitor
QRSS test is active, R
esetMon is available to reset the error counter to zero.
Selecting the Stop command on the Network Test screen or Abort Tests from the
Test menu will not disrupt a network-initiated loopback.