Paradyne 7112 Network Card User Manual


 
Standards Compliance for SNMP Traps
D-5
7112-A2-GB20-20
March 1998
The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-binding are different for each particular interface. Diagnostic tests are
only supported on the physical T1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:
Interface
enterpriseTestStart/Stop
Variable-Bindings
Possible Cause
Physical Sublayer
T1 network
H ifIndex (RFC 1573)
H ifAdminStatus
(RFC 1573)
H ifOperStatus (RFC 1573)
H ifType (RFC 1573)
H dsx1SendCode
(RFC1406)
H enterpriseTest Start – Any one
of the following tests is active
on the interface:
Remote Line Loopback
Send QRSS pattern
H enterpriseTest Stop – No
longer has any tests running
on the interface.
H ifIndex (RFC 1573)
H ifAdminStatus
(RFC 1573)
H ifOperStatus (RFC 1573)
H ifType (RFC 1573)
H dsx1LoopbackConfig
(RFC 1406)
H enterpriseTest Start – Any one
of the following tests is active
on the interface:
Line Loopback
Payload Loopback
H enterpriseTest Stop – No
longer has any tests running
on the interface.
H ifIndex (RFC 1573)
H ifAdminStatus
(RFC 1573)
H ifOperStatus (RFC 1573)
H ifType (RFC 1573)
H ifTestType (RFC 1573)
H enterpriseTest Start – Any one
of the following tests is active
on the interface:
Repeater Line Loopback
Send 1-in-8 pattern
All Monitor Pattern tests
H enterpriseTest Stop – No
longer has any tests running
on the interface.
Synchronous User
Data Ports
H ifIndex (RFC 1573)
H ifAdminStatus
(RFC 1573)
H ifOperStatus (RFC 1573)
H ifType (RFC 1573)
H ifTestType (RFC 1573)
H enterpriseTest Start – Any one
of the following tests is active
on the port:
Local Loopback (DTE)
Send 511 pattern
Monitor 511 pattern
H enterpriseTest Stop – No
longer has any tests running
on the port.