Paradyne 7112 Network Card User Manual


 
Testing
7-7
7112-A2-GB20-20
March 1998
" Procedure
To run a Monitor QRSS test:
1. Position the cursor at the Start command next to Monitor QRSS on the
Network Tests screen.
2. If desired, use Ctrl-a to switch to the screen function key area and use the
virtual function key r or R (R
esetMon) to clear the error counter to zero. Press
Ctrl-a to return the cursor to the Start command and press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command and press Enter.
The Send and Monitor Pattern tests cannot be started when any loopback is
already active on the network interface.
Running Data Port Tests
To access the Data Port Tests screen, follow this menu selection sequence:
Main Menu
Test
Data Port Tests
main/test/data PARADYNE
Device Name: Model: 7112
DATA PORT TESTS
Test Command Status Result
Local Loopbacks
Data Terminal Loopback: Start Inactive 0:00:00
Data Channel Loopback: Start Inactive 0:00:00
Remote Loopbacks
Send V.54 Loopback: Up
Send Inactive 0:00:00
Send FT1 Loopback: Down
Send Inactive 0:00:00
Pattern Tests
Send: QRSS
Start Inactive 0:00:00
Monitor: QRSS
Stop Active 99:08:48 – Errors 99999+
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
R
esetMon