Paradyne 7112 Network Card User Manual


 
Messages and Troubleshooting
8-2
7112-A2-GB20-20
March 1998
To configure SNMP Traps, follow this menu selection sequence:
Main Menu
Configuration
Load Configuration From
SNMP
SNMP Traps
Refer to Table A-10, SNMP Traps Options.
Device Messages
The Device Messages in Table 8-1, listed in alphabetical order, may appear in the
messages area at the bottom of the ATI screens.
Table 8-1. Device Messages (1 of 2)
Device Message
What Message Indicates What To Do
Cannot Save – no
Login IDs with Access
Level 1
All of the login IDs being
saved have an access level
below Level 1.
Change the access level of at
least one Login ID to Level 1 so
that configuration changes can
be made. (Levels 2 and 3 cannot
make configuration changes.)
Save the Login IDs.
Command Complete Action requested has
successfully completed.
No action needed.
Invalid Character (
x
)
1
A nonprintable ASCII
character has been
entered.
Re-enter information using valid
characters.
Invalid – Data
Terminal (or Channel)
Initiated Loopback
Active
Network-initiated loopback
was in progress when
another selection was
made.
No action needed.
Invalid Password Login is required and an
incorrect password was
entered; access is denied.
H Try again.
H Contact your system
administrator to verify your
password.
Invalid – [Test]
Already Active
The [test] was already in
progress when another
selection was made.
H Allow test to continue.
H Select another test.
H Stop the test.
Invalid Test
Combination
A loopback or pattern test
was in progress when Start
was selected to start
another test, or was active
on the same or another
interface when Start was
selected.
H Wait until other test ends and
message clears.
H Abort all tests from the Test
menu screen.
H Stop the test from the same
screen the test was started
from.
1
x
is the character not being accepted.