Paradyne 8777 Network Hardware User Manual


 
Monitoring and Troubleshooting
7-2
8700-A2-GB20-00
April 2000
Viewing System and Test Status
To view System and Test Status information, follow this menu selection
sequence:
Main Menu Status System and Test Status
main/status/system
Slot: 2 Model: 87xx
SYSTEM AND TEST STATUS Page 1 of 1
HEALTH AND STATUS SELF-TEST RESULTS TEST STATUS
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
LOS at Net, Pt n CPU Failed No Test Active
OOF at Net, Pt n Device Failed LLB Test Active, Pt n
EER at Net, Pt n Net DSL Failed, Pt n RLB Test Active, Pt n
LOS at DSX-1 Pt n DSX-1 Pt Failed, Pt n Lamp Test Active
Net Margin Threshold, Pt n Memory Failed DLB Test Active, Pt n
Device Failed yyyyyyyy Passed
Download Failed
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ESC for previous menu M
ainMenu Exit
The System and Test Status screen has three sections:
H Health and Status Displays messages in priority order (highest to lowest).
Refer to Table 7-1, Health and Status Messages.
H Self-Test Results Results of the Diagnostic test run on the device itself.
Refer to Table 7-2, Self-Test Results Messages.
H Test Status Currently active tests. Refer to Table 7-3, Test Status
Messages.