Paradyne 8777 Network Hardware User Manual


 
Configuration Options
A-3
8700-A2-GB20-00
April 2000
Table A-1. Network Interface Options (2 of 3)
Excessive Error Rate Threshold
Possible Settings: 1E4, 1E5, 1E6, 1E7, 1E8, 1E9
Default Setting: 1E6
Determines the error rate at which an excessive error rate (EER) condition is
recognized. The rate is the ratio of the number of CRC errors to the number of bits
received in a certain period.
AutoRate
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the unit automatically adjusts to the best line rate for conditions, or
is fixed at the rate in the DSL Line Rate field. The automatically set rate cannot exceed
Max DSL AutoRate.
H AutoRate is only available when the unit is configured as an LTU.
Enable The LTU adjusts to the best line rate.
Disable The LTUs line rate is the DSL Line Rate selected.
DSL Line Rate
Possible Settings (Models 8747, 8777): 144, 272, 400, 528, 784, 1040, 1552
Default Setting: 1552
Possible Settings (Model 8779): 144, 272, 400, 528, 784, 1040, 1552, 2064
Default Setting: 2064
Determines the fixed line rate of the LTU when AutoRate is disabled. See Tables A-2
and A-3 for information about maximum payload rates for different DSL line rates.
H DSL Line Rate is only available when the unit is configured as an LTU and
AutoRate is disabled.
144 to 2064 The fixed DSL Line Rate, in kbps.
Max DSL AutoRate
Possible Settings (Models 8747, 8777): 144, 272, 400, 528, 784, 1040, 1552
Default Setting: 1552
Possible Settings (Model 8779): 144, 272, 400, 528, 784, 1040, 1552, 2064
Default Setting: 2064
Determines the maximum rate the unit can AutoRate to. See Tables A-2 and A-3 for
information about maximum payload rates for different DSL line rates.
H Max DSL AutoRate is only available when the unit is configured as an LTU and
AutoRate is enabled.
144 to 2064 The AutoRate ceiling, in kbps.
EIA-530 Payload Rate
Possible Settings: 64, 128
Default Setting: 128
Specifies the synchronous port speed of the remote NTU if the NTU is an EIA-530
model and the DSL line rate is 144 kbps. At higher line rates the EIA-530 NTU runs at
the highest payload rate possible.
H EIA-530 Payload Rate is only available when the unit is configured as an LTU.
64 or 128 The synchronous port speed of the remote NTU, in kbps.