Paradyne 8777 Network Hardware User Manual


 
Configuration Options
A-11
8700-A2-GB20-00
April 2000
System Options
For System Options, refer to Table A-7. To access the System Options screen,
follow this menu selection sequence:
Main Menu Configuration Load Configuration From System
main/config/system
Slot: 18 Model: 87xx
SYSTEM OPTIONS
DSL Mode: LTU
Test Timeout: Enable
Test Duration (min): 10
Telco Initiated Loopbacks: Enable (Models 8747, 8777)
Remote Telco Line Loopback: Disabled
(Models 8747, 8777)
G.703 Line Termination 120 Ohm
(Model 8779)
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
S
ave
Table A-7. System Options (1 of 2)
DSL Mode
Possible Settings: LTU, NTU
Default Setting: LTU
Controls whether the unit is configured as a control unit or tributary unit.
LTU The unit is configured as a control unit (Line Termination Unit).
NTU The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.
NOTE: Changing this option will reset the card.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is
remotely managed, so that control can be regained after a test is accidentally executed.
Enable Loopback and pattern tests end when test duration is reached.
Disable Tests run until manually terminated from the Network Tests screen or
remotely (network initiated tests). Refer to Running Network Tests in Chapter 8, Testing.
Test Duration (min)
Possible Settings: 1120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H Test Duration (min) option appears when Test Timeout is enabled.
1 to 120 Amount of time in minutes for a test to run before terminating.