Paradyne 7924 Network Card User Manual


 
Monitoring the Unit
6-2
7924-A2-GB20-30
October 1997
Board Status
Board Status option from the Main Menu displays HDSL circuit operational status.
Enter 1 at the Main Menu Command prompt to display board status.
Command 1
T1 STATUS: Network is UP
LOOPBACK STATUS: OFF
HDSL STATUS: LOOP A is UP, LOOP B is UP
S/N RATIO: Loop A = 44.0 dB, Loop B = 43.5 dB
Command
Board Status for DSX-1-Compatible Unit
Command 1
DTR: ACTIVE
DSR: ACTIVE
LOOPBACK STATUS: OFF
HDSL STATUS: LOOP A is UP, LOOP B is UP
S/N RATIO: Loop A = 44.0 dB, Loop B = 43.5 dB.
Command
Board Status for V.35-Compatible Unit
H T1 STATUS displays one of the following:
Network is Up
Receive Carrier Loss
Receive Remote Alarm
Receive Unframed All 1’s.
H DTR and DSR are either ACTIVE or INACTIVE. DSR becomes active in
response to DTR (with HDSL loops up and data transmission possible).
H LOOPBACK STATUS is either ON or OFF.
H HDSL STATUS displays whether each loop is UP, DOWN, or DISABLED.
H S/N (Signal-to-Noise) RATIO is not displayed if loops are down or disabled.