Paradyne 7924 Network Card User Manual


 
Worksheets
A-3
7924-A2-GB20-30
October 1997
DSX-1-to-V.35 Configuration
Router
V.35 Unit
V.35
LAN
Customer Premises
DSX-1
DSX-1
Central Site
Cross-campus
2- or 4-wire
facility
97-15420
Multiplexer
To connect a V.35-compatible unit on the CP side and a DSX-1-compatible unit
on the CO side, configure the units as follows. Terminal mode factory defaults are
in bold (for Switchpack mode defaults, see Appendix C,
Switchpacks and
Jumpers
).
Configuration
Option
V.35-Compatible Unit
(Customer Premises)
DSX-1-Compatible Unit
(Central Site)
Card Type CP CO
Loops Enabled Dual (Loops A & B) or
Single (Loop A)
Must be same as CP side
Payload Rate 1 – 9 (64 – 1536 kbps)
Options 8 (1024 kbps) and 9
(1536 kbps) are only available
if both Loops A & B are
enabled.
N/A
Framing N/A Use D4, Extended Superframe, or
Unframed. See
Unframed
Operation
on page A-4 before
selecting Unframed.
T1 Line Encode N/A B8ZS or AMI
Line Build-Out N/A Enter 5 at the Config command
prompt. Select from the following
options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft