DSX-1-to-DSX-1 Configuration
Multiplexer
DSX-1 Unit
DSX-1
Multiplexer
DSX-1 Unit
DSX-1
Cross-campus
2- or 4-wire
facility
Customer Premises
Central Site
97-15296
To connect two DSX-1-compatible units, configure the units as follows. Terminal
mode factory defaults are in bold (for Switchpack mode defaults, see Appendix C,
Switchpacks and Jumpers
).
Configuration
Option
DSX-1-Compatible Unit
(Customer Premises)
DSX-1-Compatible Unit
(Central Site)
Card Type CP (default) CO
Loops Enabled Dual (Loops A & B) or
Single (Loop A)
Must be same as CP side
T1 Line Encode B8ZS or AMI Must be same as CP side
Framing D4, Extended Superframe,
or Unframed
Must be same as CP side
Line Build-Out Enter 5 at the Config
command prompt. Select
from the following options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft
Enter 5 at the Config command
prompt. Select from the following
options:
1) 0 to 133 ft
2) 133 to 266 ft
3) 266 to 399 ft
4) 399 to 533 ft
5) 533 to 655 ft