Patton electronic 2710 Switch User Manual


 
39
APPENDIX B
PATTON NETLINK-T1™ MODEL 2710
CABLE RECOMMENDATIONS
The Patton NetLink T1™ Series has been performance tested by
Patton technicians using twisted-pair cable with the following charac-
teristics:
Wire Gauge Capacitance Resistance
19 AWG 83nf/mi or 15.72 pf/ft. .0163 Ohms/ft.
22 AWG 83nf/mi or 15.72 pf/ft. .0326 Ohms/ft.
24 AWG 83nf/mi or 15.72 pf/ft. .05165 Ohms/ft.
To gain optimum performance from the Model 2710 Series, please
keep the following guidelines in mind:
Always
use twisted pair wire—this is not an option.
• Use twisted pair wire with a capacitance of 20pf/ft or less.
• Avoid twisted pair wire thinner than 26 AWG (i.e. avoid AWG
numbers higher than 26)
• Use of twisted pair with a resistance greater than the above
specifications may cause a reduction in maximum distance obtain-
able. Functionality should not be affected.
• Many environmental factors can affect the maximum distance
obtainable at a particular site.
40
APPENDIX C
PATTON NETLINK-T1™ MODEL 2710
FACTORY REPLACEMENT PARTS
AND ACCESSORIES
Patton Model #
Description
2710/CM/120...................T1 Nx64 CSU/DSU(M/34 Male, 120VAC)
2710/CM/UI .....................T1 CSU/DSU (V.35 M/34 Male, UI)
10 - 09F...........................6 Foot Control Port Cable, 25 mm to
DB9F
07M2710 .........................User Manual