Pelco KBR960 Computer Keyboard User Manual


 
12 C1519M-D (3/06)
SETUP MODE
You can configure the KBD960 in the Setup Mode. You can do the following:
Create a Personal Identification Number (PIN) for entering the Setup Mode.
Create a PIN that provides access to features on the Define Menu.
Calibrate the joystick.
Adjust the display brightness.
Set the data transmission speeds for the keyboard’s three COM ports.
Define the function keys.
Select a host port.
The default setup PIN is 1234. You can change it in the Setup Mode.
ACTIVATING SETUP MODE
1. Set DIP Switch 2 ON. “ENTER SETUP PIN” appears.
2. Enter your PIN number (the default number is 1234) and “SETUP MODE”
appears.
CALIBRATING THE JOYSTICK
1. Select
JSTK
from Setup Mode. “JOYSTICK SETUP” appears on the LCD.
2. Select with the joystick in the center default position.
3. Move the joystick completely to the left and select .
4. Move the joystick completely to the right and select .
5. Move the joystick completely down and select .
6. Move the joystick completely up and select .
7. Select to save the joystick configuration.
8. Select to return to the Setup Menu.
RESTORING FACTORY DEFAULT SETTINGS
1. Set DIP switches 1, 2, and 8 ON and recycle power.
2. Re-calibrate the joystick if using a keyboard version before 1.20.
For version 1.20 and later keyboards, the joystick is automatically calibrated
during a factory default initialization.
ENTER SETUP PIN
00895
SETUP MODE vX.XX
ADVLCD
JSTK
00896
Figure 3. Enter Setup PIN
Figure 4. Setup Mode
JOYSTICK SETUP
xxx
(xxx, xxx)
xxx
xxx
xxx
00897
Figure 5. Joystick Setup