Pelco NSM5200 Computer Drive User Manual


 
C3683M (3/09) 27
Specifications
SYSTEM
Operating System Linux
RAID Level CompactFlash system drive, RAID 6 for storage drives
Effective Capacity Up to 9.082 TB, expandable with DAS5200s
Drive Interface SAS/SATA II
User Interface Remote operation from Endura workstation or VCD5000
Minimum Requirements Microsoft
®
Internet Explorer
®
6.x or higher with Adobe
®
Flash
®
Player 10 or later
NETWORK
Interface 2, 1 Gbps Ethernet RJ-45 ports (1000Base-T)
Auxiliary Interfaces
USB 2.0 3 ports: 2 ports on rear panel, 1 port on front panel
FRONT PANEL INDICATORS
Power Blue Pelco badge
Software Status Green, Amber, Red (based on diagnostics)
Ethernet Port 1 Green, Amber, Red
Ethernet Port 2 Reserved
Hardware Status Green, Amber, Red
Hard Drive Status Green, Red
POWER
Power Input 100 to 240 VAC, 50/60 Hz, autoranging
Power Supply Internal, dual-redundant, hot-swappable
Power Consumption Operating Average
262 W, 2.65 A, 895 BTU/H
263 W, 2.31 A, 895 BTU/H
254 W, 1.25 A, 868 BTU/H
Power Cord 1, USA standard (117 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or
1, European standard (220 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or
1, UK standard (250 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or
2, Australian (250 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or
2, Argentinian (250 VAC, 3 prongs, molded connector, 8 ft or 2.4 m)
NOTE: Units shipped to China do not include power cords.
ENVIRONMENTAL
Operating Temperature 50° to 95°F (10° to 35°C) at unit air intake
Storage Temperature -40° to 149°F (-40° to 65°C)
Operating Humidity 20% to 80%, noncondensing
Maximum Humidity Gradient 10% per hour
Operating Altitude -50 to 10,000 ft (-16 to 3,048 m)
Operating Vibration 0.25 G at 3 Hz to 200 Hz at a sweep rate of 0.5 octave/minute
NOTE: The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configuration,
floor layout, air conditioning strategy, and other issues. To prevent performance failure and unit damage, make sure the temperature at the unit is