Automatic Power OFF
The plasma display is equipped with automatic power-
management and auto-power-off functions, which allow
the unit to automatically switch to power-saving mode
when no sync signal is detected.
(A warning message appears on-screen before these
functions operate.)
Notes
÷ Power management settings are supported only when a
computer signal is input to INPUT 1, or when INPUT 5 is
selected.
÷ The auto-power-off function can be used only in those cases
other than the inputs used in the preceding item.
÷ Always turn off the plasma displays main power switch when
not using the display for extended periods of time.
1 Press MENU to display the menu screen.
MAIN MENU INPUT1
SELECT ENTER EXIT
SET
MENU
PICTURE SCREEN SET UP OPTION
:
0
:
6
+
+
+
0
:
60
:
60
:
0
:
0
CONTRAST
:
0
BR
RLEVEL
IGHT.
.
GLEVEL.
BLEVEL.
H ENHANCE.
V ENHANCE.
RSETE
2 Press 2/3 to select SET UP.
[When computer signal is input to INPUT 1, or
when INPUT 5 is used]
SELECT ENTER EXIT
SET
MENU
PICTURE SCREEN SET UP OPTION
:
V
GA
:
N
T
:
A
UTO
SETTIN
CLAMP
POWER
:
G
O
FF
PSITIONO
MNAGEMEA
INPUT INPUT
1
LEBLA
MAIN MENU INPUT1
[In all other cases]
SELECT ENTER EXIT
SET
MENU
PICTURE SCREEN SET UP OPTION
:
V
GA
:
:
A
UTO
SETTIN
CLAMP
AUTO POWER
:
G
O
FF
O
FF
PSITIONO
INPUT INPUT
2
LEBLA
MAIN MENU INPUT2
3 Press 5/ to select either the POWER
MANAGEMENT or AUTO POWER OFF mode.
[When computer signal is input to INPUT 1, or
when INPUT 5 is used]
SELECT CHANGE EXIT
SET
MENU
PICTURE SCREEN SET UP OPTION
:
A
UTO
SETTIN
CLAMP
POWER
:
G
O
FF
PSITIONO
MNAGEMEA
INPUT INPUT
1
LEBLA
:
V
GA
:
N
T
MAIN MENU INPUT1
[In all other cases]
PICTURE SCREEN SET UP OPTION
:
V
GA
:
A
UTO
SETTIN
CLAMP
AUTO POWER
:
G
O
FF
O
FF
PSITIONO
INPUT INPUT
2
LEBLA
:
MAIN MENU INPUT2
4 Press SET to confirm selection of the POWER
MANAGEMENT or AUTO
POWER OFF.
÷ When OFF is selected, the display will continue in
operating mode, regardless of the presence/absence of
an input sync signal.
÷ When POWER MANAGEMENT: ON is selected, the
display automatically enters the power-saving mode
(*1) and the STANDBY/ON indicator blinks green
whenever a sync signal is not detected. If a sync signal
(*2) is input again later, the plasma display
automatically returns to normal operating mode.
*1. Power consumption is about 1 W when INPUT 1 is
used, and about 50 W when INPUT 5 is used.
*2. Except when input signal is G on SYNC or composite
SYNC
÷ When AUTO POWER OFF: ON is selected, if no sync
signal is detected for 8 minutes or more, a warning
message will be displayed for 30 seconds, after which
the displays power will switch to STANDBY mode.
5 When the setup is finished, press MENU to exit
the menu screen.
Note
The POWER MANAGEMENT and AUTO POWER OFF functions
must be set individually for each input (INPUT1-5).
To return to operating mode:
÷ To return to normal operation from POWER
MANAGEMENT mode: either operate the computer, or
press INPUT on the display or remote control unit.
÷ To return to normal operation from AUTO POWER OFF
mode: Press STANDBY/ON on the display or remote
control unit.