Planet Technology IKVM-1000 Switch User Manual


 
8
The default super user password is pass. It is recommended to change the su-
per user password as soon as you get this device.
The Wireless LAN Configuration field is left for future enhancement.
3.3 Configuration via Serial Port
Using a serial terminal, the IKVM-1000 has a serial line interface (host side). This
connector is compliant with the RS 232 serial line standard. The serial line has to
be configured with the parameters given as below.
Parameter Value
Bits/second 115200
Data bits 8
Parity No
Stop bits 1
Flow Control None
When configuring with a serial terminal, press the reset button of IKVM-1000 and
immediately press the ESC key on the keyboard of administrative PC. You will
see some device information, and a => prompt. There are four commands
available.
config: start configuration tool after boot up
defaults: set the device settings to factory defaults
help: print online help
reset: perform a soft reset
When using config command, the following interactive options will appear:
IP auto configuration (non/dhcp/bootp) [dhcp]:
With this option, you can specify whether the IKVM-1000 should get its
network settings from a DHCP or BOOTP server. For DHCP, enter dhcp,
and for BOOTP enter bootp. If you do not specify any of these, the IP auto
configuration is disabled and subsequently you will be asked for the
following network settings.
IP [192.168.1.1]:
This is the current IP address of the IKVM-1000. This option is only
available if IP auto configuration is disabled.
Net mask [255.255.255.0]: