PSC PT2000 Scanner User Manual


 
Overview
User’s Guide 91
Table A-4: Serial Programming Parameters
Code Parameter ID # Type Acceptable Input
Predefined Default
(C8)
Enter 1 for On and 0 for Off.
Host select
C0 Value 11 = ATs, PS/2s, and
compatibles
15 = IBM terminals
None
Baud rate
C1 Value
00 = 300
01 = 600
02 = 1200
03 = 2400
04 = 4800
05 = 9600
06 = 19,200
07 = 38,400
08 = 76,800
05
Data bits
C2 Value
07 = 7 bits
08 = 8 bits
08
Parity
C3 Value
00 = None
03 = Odd
04 = Even
00
Stop bits
C4 Value
01 = 1 bit
02 = 2 bits
01
Enable Xon/Xoff
C5 On/Off On or Off Off
Linefeed (LF)
(Valid for CA = 00 only)
C6 Value
00 = None
01 = Strip LF
02 = Add LF
00
Predefined serial defaults
C8
End-of-file character
C9 Value Any single ASCII
character
1A
Protocol
CA Value 00 = EOR only
01 = CR with checksum
and ACK/NAK response
02 = Xmodem
01
End-of-record (EOR) character
CC Value Any single
ASCII character
(CR)
Timeout
CD Value 00–99
(100-millisecond units)
10
PT2000.book Page 91 Thursday, February 26, 2004 9:34 AM