Quatech IN5000 Server User Manual


 
Quatech, Inc. AirborneDirect™ User Manual
134 2/21/2011 100-8510-110
26.0 Physical & Environmental Approvals
The device has passed the following primary physical and environmental tests. The test
methods referenced are defined in SAE J1455 Aug1994.
Table 49 - Mechanical Approvals
Test
Reference
Conditions
Temperature Range
(Operational)
Table 1B, Type 2b
-40°C to +85°C
Temperature Range (Non-
Operational)
-50°C to +125°C
Humidity
Sect 4.2.3
0-95%RH @ 38°C condensing
Fig 4a 8 hours active humidity cycle
Altitude
Sect 4.8
Operational: 0-12,000ft (62 KPa absolute pressure)
Non-operational: 0-40,000ft (18.6 KPa absolute
pressure)
Vibration
Sect 4.9
Operational: 2.4 Grms, 10-1K Hz, 1hr per axis
Non-operational: 5.2 Grms, 10-1K Hz, 1hr per axis
Shock
Sect 4.10
Operational: 20Gs MAX, 11ms half-sine pulse
Product Drop
Sect 4.10.3.1
1m onto concrete, any face or corner, 1 drop
Packaging Drop
Sect 4.10.2.1
32 inches onto concrete on each face and corner.
Packaged in ‘for transit’ configuration.
Test reports are available from Quatech Technical Support, please contact directly for the