Quatech IN5000 Server User Manual


 
AirborneDirect™ Users Guide Quatech, Inc.
100-8510-110 2/21/2011 19
Table 2 - Serial Ports by Product Class
Device Class
Port 1
Port 2
Enterprise
RS232
RS422 (4-wire)
RS485 (2-wire)
N/A
Industrial
RS232
RS422 (4-wire)
RS485(2-wire)
N/A
RS232
RS422 (4-wire)
RS485(2-wire)
RS232
RS422 (4-wire)
The Port 1 and Port 2 interfaces support the following configurations:
BAUD: 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400,
57600, 115200, 230400, 460800, 921600
Flow Control: None, Hardware (CTS/RTS), Software (XON/XOFF)
Port 1 Default settings: 9600, 8, N, 1, No Flow Control.
Port 2 Default settings: 9600, 8, N, 1, No Flow Control.
6.2 Ethernet Port
The AirborneDirect Ethernet devices support a single interface. This is a
10/100Mbps interface that supports auto negotiation and cross-over cabling. The
interface also supports both half and full duplex for 10Mbps and 100Mbps. Table
XX shows the interface pin out.
Figure 7 - Ethernet Jack Pin Out
Table 3 - Ethernet Connector Pin Out
Pin
RJ45 Socket (Industrial)
RJ45 Plug (Enterprise)
1
TxD+
RxD+
2
TxD-
RxD-
3
RxD+
TxD+
4
NC
NC
5
NC
NC
6
RxD-
TxD-
7
NC
NC