RAD Data comm ASM-60 Network Router User Manual


 
ASM-60 Installation and Operation Manual Chapter 4 Management from a Terminal
Starting the Control Session 4-3
Terminal Management Menus
Figure 4-1 shows a map of the management menus in the ASM-60 embedded
software. The second level menus (Configuration, Display, Reset) are described in
its own section in this chapter. The Alarms, Log File, VDSL Performance and Test
menus are described in Chapter 5.
4. Reset 5. Debug3. Test
1. Start LEDs Test 1. Factory Setting
2. Reset Device
3. Reset Device
4. Reset FPGA
1. Configuration
1. Data Rate
1. 4096 kbps
2. 6144 kbps
3. 10240 kbps
2. Display
1. Status
4. VDSL Performance
3. Log File
2. Alarms
Main Menu
Figure 4-1. ASM-60 Management Software
The Debug option is reserved for the use only by the authorized personnel.
4.3 Starting the Control Session
Once you have installed the ASM-60 modems at the central and remote locations,
and completed the installation and operation procedures described in Chapter 2
and Chapter 3, you can start the control session.
When the communication link between the modems is established, the ASM-60
software identifies the unit type (ASM-60/CO or ASM-60/CPE), and runs the
start-up self-test.
During the initialization, the following message is displayed:
Initializing ASM-60/CO or Initializing ASM-60/CPE
If errors were detected during the self-test, ASM-60 displays the following message:
Initialization Failed
If the self-test is successful, ASM-60 displays the Main menu (see Figure 4-2).
Note