Raymarine ST60 Tridata Personal Computer User Manual


 
Chapter 3: Installation 19
2. Apply the surface mount template (suppliedat the rear of this hand-
book)totheselectedlocationandmarkthecentresforthefixingstuds
(1) and the aperture (3) that willtakethe rear casing of the instrument.
3. Drill out the two 5 mm fixing stud clearance holes (2).
4. Cut out the clearance hole (3) then remove the template.
5. Peel offthe protective sheet from the self-adhesive gasket (4) then
stick the gasket into position onthe rear of the instrument.
6. Screwthe two fixingstuds intothe threadedsockets ontherear of the
instrument.
7. Mount the assembled instrument, studs,bezel and gasket into the
panel. Securefrom behind with the thumb nuts (5).
Flush mounting
The Flush Mounting Kit uses a low-profile bezel to reduce the fitted
profile of the instrument, to approximately 6 mm above the panel fascia.
D4343-2
Surface mounting
11223455
81040_1.book Page 19 Thursday, November 7, 2002 10:21 AM