Raymarine ST60 Tridata Personal Computer User Manual


 
Calibration 39
Leaving Intermediate calibration
Holddownthedepth andspeedkeysfor2seconds,tosaveyoursettings,
exit Intermediate calibration and resume normal operation.
4.4 Dealer calibration
The Dealer calibration procedures enable the following parameters to be
set:
User calibration on/off.
Speed response.
Depthresponse.
Boat show mode on/off.
Dealer calibration also gives access to the Factory defaults screen. This
enables you to re-apply the factory settingsif you want to reset the
instrument to a known operating condition.
To commence Dealer calibration, hold down the
depthandspeed keys
together for approximately 12 seconds, to select the Dealer calibration
entrypage (seeDealer calibration diagram). Then press the
trip and
reset keystogether, to enter the calibration screen sequence.
Use the depth key to move from screen to screen and the trip or the rest
key to set the required values at each screen.
User calibration on/off
Press either thetripor reset keyto togglethe User calibrationonor offas
required.Withoffselected, User calibration and Intermediate calibration
are both disabled.
Response settings
The response values for both SPEEDand DEPTH determine the frequency
at which information is updated. A low number provides a smooth
response and a high number a much livelier update.
Usethe
trip (decrement) and reset (increment) keys to set the required
value. Response values are from 1 to 15.