Chapter 3: Installation 21
Flush mounting procedure
Flushmount your instrument (see the Flush mountingillustration) as
follows:
1. Assemble the ST60 instrument and low-profile bezel as described
under Fitting the low-profile bezel.
2. Ensure that:
Thepanel on which you intend to mount the instrument is
between 3 mm and 20 mm thickness.
Theselected location is clean, smooth and flat.
Thereis sufficient space behind the selected location to accom-
modate the rear of the instrumentand connectors.
3. Apply the flushmount template (supplied at the rear of this hand-
book) to the selected location and mark out the aperture into which
the assembled instrument and bezel will sit.
4. Cut out the aperture (3) for the assembled instrument and bezel and
remove the template.
5. Peel offthe protective sheet from the self-adhesive gasket (4) then
stick the gasket into position on the rear of the bezel.
D4362-2
789
Fitting the low profile bezel
81040_1.book Page 21 Thursday, November 7, 2002 10:21 AM