34 ST60 Tridata Instrument Owners Manual
4.3 Intermediate calibration
Intermediate calibration enables you to:
Check the instrument software version.
Checkthe instrument status- eitherYES (master)) or NO (repeater).
You can also change the depth status, as required. This feature is par-
ticularly usefulin preventing interference when using another prod-
uct (e.g. a fishfinder) that operates at 200 kHz.
Carry out a calibration run over a measured distance to ensure accu-
rate speed readings.
To start Intermediate calibration,hold down the
depth and speed keys
for approximately 4 seconds(see Intermediate calibration flow chart).
To set the instrument status:
1. Press the
depth key to select the Instrument status screen.
2. Press the
trip andreset keys simultaneouslyto enterthe depth adjust
mode, then press either
trip or reset to set the required status, i.e.
either YES(for master operation) or NO (for repeater operation).
Note: You must not allocate more than one master depth instrument in
any system.
3. Pressthe trip and reset keys simultaneously again, to leave the adjust
mode.