Address STD1[7:0] (L) STD2[15:8] (H)
11110100 D4D3D2D7 D6 D5 D1 D0 D12 D11 D10 D9 D8
Gray_test
VD latch MON
Gray code
H12_Buff
MON (D0 to D2 of address H’F4)
Select the pulse which output to pin MON (pin 60).
When D0 to D2: 0, Fix to Low When 1, ADCLK
When 2, SP1 When 3, SP2
When 4, OBP When 5, PBLK
When 6, CPDM When 7, DLL_test
H12Baff (D3 to D6 of address H’F4)
Select the buffer size which output to pin H1A, H2A (pin 22, 26).
D3: 2 mA buffer
D4: 4 mA buffer
D5: 10 mA buffer
D6: 14 mA buffer
Above data can be on/off individually. Default is D6 can be on only. (18 mA buffer)
VD latch (D7 of address H’F4)
Data = 0: Gain data is determined when CS rising
Data = 1: Gain data is determined when VD falling
Differential Code and Gray Code (D8 to D12 of address H’F4)
Gray code (D8 to D9 of address H’F4)
DC output code can be change to following type.
Gray Code [1] Gray Code [0] Output Code
0 0 Binary code
0 1 Gray code
1 0 Differential encoded binary
1 1 Differential encoded gray
Serial data setting items (D10 to D12 of address H’F4)
Setting Bit Setting Contents
Gray_test[0]
Gray_test[1]
Standard data output timing control signal
(Refer to the following table)
Gray_test[2] ADCLK polar with OBP. (LoPositive edge, HINegative edge)
Standard data output timing
Gray_test[1] Gray_test[0] Standard Data Output Timing
Low Low Third and fourth
Low High Fourth and fifth
High Low Fifth and sixth
High High Sixth and seventh