3.4 Connecting the PC4701
To connect the emulation pod to the PC4701, use the FLX120-RPD 120-pin flexible cable included
in this product package. Connect the PC4701 side connector of the FLX120-RPD to the cable
connector of the PC4701, then secure with screws.
(1) Connecting the Cable to the PC4701
Figure 3.8 shows how to connect the PC4701 and FLX120-RPD.
Figure 3.8 Connecting the PC4701 and FLX120-RPD
CAUTION
Note on Connecting the Cable:
To connect the FLX120-RPD, be sure to hold the both sides of the PC4701 side
connector horizontally with the "UPSIDE" facing up.
Always shut OFF power before connecting the cable. The power ON state could
destroy internal circuits.
Note on Securing the Screws:
After connecting the emulator main unit to the FLX120-RPD, be sure to secure the
screws.