C: Misfeed in the transport area
1
Lower the fusing unit release lever.
See "B: Misfeed in the fusing area" (p.65).
2
Open the front cover.
To open the front cover, see "INSTALLING THE TD CARTRIDGE" (p.10).
3
Rotate the roller rotating
knob in the direction of the
arrow and gently remove
the misfed paper from the
exit area.
4
Raise the fusing unit release lever, close the front cover and
then close the side cover by pressing the round projections
near the side cover open button. The misfeed ( ) indicator will
go out and the start ( ) indicator will light up.
D: Misfeed in the lower paper feed area
1
Open the lower side cover
(under the multi-bypass
tray) and remove the misfed
paper. If the misfeed ( )
indicator blinks and the
misfed paper is not seen
from the area of the lower
side cover, pull out the
lower paper tray and remove
the misfed paper. Then
close the lower paper tray.
2
Close the lower side cover.
3
Close the side cover by pressing the round projections near
the side cover open button. The misfeed ( ) indicator will go
out and the start ( ) indicator will light up.
When closing the covers, be sure to close the front cover securely and
then close the side cover. If the covers are closed in the wrong order, the
covers may be damaged.
Roller rotating knob