Seiko Instruments DPU-30 Printer User Manual


 
5-8
SI Double–Width Printing Mode Clear
Code
0F
16
Function
Clears the doublewidth printing.
CAN Cancel
Code
18
16
Function
Clears the print buffer.
Details
After executing this command, a head of a line is set as a starting position of
printing.
ESC S n1 n2 n3 n4 Bitimage Graphic
Code
1B
16
+ 53
16
+ n1 + n2 + n3 + n4 + [DATA]
Domain of
function
30
16
n1, n2, n3, n4 39
16
“0001” “n1 n2 n3 n4” “1023”
0 d 255 (graphic data)
Function
The number of data specified in ASCII code n1, n2, n3 and n4 are specified as a
Bitimage.
Example: Case that 192 Bitimages are specified
1B
16
+ 53
16
+ “0192” + . . . . . . . . .
[192 DATA]
Details
The code outside the domain of function processes the data as the 1-byte data
thereafter.
If the dots are specified outside the printing area, the data is ignored.
The data deployment position is set in accordance with the predefined starting
position of the data deployment.
This command is affected by the inverse printing.
If the next Bitimage Specify command is received at the occurrence of the line
overflow, the data of the previous line stored in the print buffer is printed. The line
overflow is determined according to the number of dots described below.
Mode 1: Determined as the line overflow if the number of dots exceeds 276.
Mode 2: Determined as the line overflow if the number of dots exceeds 332.
Refer to the figure shown below for how the data is deployed.