5-36
DLE EOT n Status Transmit in Real Time
Code
10
16
+ 04
16
+ n
Domain of
function
n = 1
Function
Returns the current printer status in real time.
Details
• Regardless of the validity of the automatic status response, this function returns
the current status.
• For the status values, refer to Table 5-1 Status Response Value Table.
• This command is executed at the reception.
• When the real time command is invalid, this command is ignored.
• Users should be aware that even if this command is valid and consistent with
DLE ENQ 1 in the image data, this command will be executed.
Table 5-1 Status Response Value Table
Description
Response value
(1 byte)
Printer status
0 1
Bit 0 Out-of-paper error no error error
Bit 1 Cover open error no error error
Bit 2 Voltage error no error error
Bit 3 Temperature error no error error
Bit 4 Printer operation standby operating
Bit 5 Fixed to 1 − fixed
Bit 6 Fixed to 1 − fixed
Bit 7 Fixed to 0 fixed −