Seiko Instruments DPU-30 Printer User Manual


 
5-20
ESC G n
ESC E n Bold Characters Specify and Clear
Code
1B
16
+ 47
16
+ n
1B
16
+ 45
16
+ n
Domain of
function
0 n 255
Function
Specifies and clears the bold characters.
n = <xxxxxxx0>B: The bold characters are cleared.
n = <xxxxxxx1>B: The bold characters are specified.
Details
n is valid only for the least significant bit.
In default, n = 0.
ESC { n Inversion (Flip) Specify and Clear
Code
1B
16
+ 7B
16
+ n
Domain of
function
0 n 255
Function
Specifies and clears the inversion.
n = <xxxxxxx0>B: The inversion is cleared.
n = <xxxxxxx1>B: The inversion is specified.
Details
n is valid only for the least significant bit.
This setting is valid only at a head of a line.
In default, n = 0.